POLLTECH INSTRUMENTS PRIVATE LIMITED
GST : 27AAFCP5116Q1ZY

call images

Call us

08037735881

PEM-HHS-1X Halogen And Halides Sampling Equipment
PEM-HHS-1X Halogen And Halides Sampling Equipment

PEM-HHS-1X Halogen And Halides Sampling Equipment

MOQ : 1 Piece

PEM-HHS-1X Halogen And Halides Sampling Equipment Specification

  • Automation Grade
  • Manual
  • Test Range
  • As per method requirements
  • Humidity
  • Up to 85% RH
  • Features
  • Easy glass tube replacement, corrosion-resistant body
  • Application
  • Halogen and Halides determination in samples
  • Mounting Type
  • Bench-top
  • Number of Specimens
  • 1 at a time
  • Port Size
  • 6 mm OD hose connection
  • Specimen Size
  • Tube type - 18 mm ID x 150 mm length
  • Accuracy
  • Depends on method and reagents
  • Response Time
  • Method-dependent
  • Temperature
  • Ambient to 60C
  • Max Height
  • Approx. 350 mm
  • Operating Voltage
  • 230V AC
  • Equipment Type
  • Sampling Equipment
  • Gas Pressure
  • 0.5 to 1 Kg/cm2
  • Power Supply
  • 230V AC, 50Hz
  • Measuring Range
  • Method-dependent
  • Interface Type
  • Manual control
  • Display Type
  • No digital display
  • Frequency
  • 50 Hz
  • Usage
  • Laboratory sampling for halogen & halide analysis
  • Capacity
  • One sample per run
  • Machine Weight
  • Approx. 6 Kg
  • Test Speed
  • Standard
  • Test Width
  • Glass tube 18 mm ID
  • Control Mode
  • Manual
  • Operation
  • Unheated, requires external heating if needed
  • Work Environment
  • Laboratory, Analytical Usage
  • Accessories Provided
  • Glass tube, tubing, holder, sample bottle
  • Dimensions
  • 375 mm x 220 mm x 350 mm (L x W x H)
  • Compliance Standards
  • Follows BIS/ASTM/IEC testing methods
  • Sample Introduction
  • Via tube and bottle inlet
  • Flow Meter Type
  • Rotameter provided for flow indication
  • Material of Construction
  • Mild steel epoxy powder coated and borosilicate glass
  • Safety Features
  • Gas leak-proof joints, over-pressure protection
 

PEM-HHS-1X Halogen And Halides Sampling Equipment Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

About PEM-HHS-1X Halogen And Halides Sampling Equipment



Discover the PEM-HHS-1X Halogen and Halides Sampling Equipment, an extraordinary solution crafted from mild steel with epoxy powder coating and borosilicate glass. With favorable reviews for its splendid corrosion resistance and commanding safety features, this bench-top unit is ideal for laboratory analytical use. An integrated rotameter ensures precise flow indication, while gas leak-proof joints and over-pressure protection maximize safety. Accessories like the glass tube and sample bottle, alongside compliance with BIS/ASTM/IEC standards, make this manual, method-driven equipment a trusted choice for reliable halogen and halide determination. Order now to explore exceptional sampling accuracy.

Sophisticated Usage and Features

To operate the PEM-HHS-1X, simply introduce your sample via the tube and bottle inlet, ensuring laboratory bench-top placement. Designed for analytical work, it offers easy glass tube replacement, corrosion-resistant mild steel body, and manual control. Its splendid rotameter visualizes flow, and gas leak-proof joints provide top-tier safety. The unheated operation supports external heating if needed, delivering flexibility for halogen and halide analysis on diverse laboratory surfaces.


Quality Assurance, Sample Availability, and Transaction Terms

The PEM-HHS-1X is associated with premium certifications that guarantee methodical accuracy and reliability. For your convenience, sample units can be handed over upon request, ensuring confidence before purchase. Every piece is carefully packaged to protect its splendid construction during transit. Flexible payment terms are offered to streamline your procurement experience. Trust this manufacturer, service provider, and supplier in India for your laboratory's halogen and halide sampling needs.


FAQ's of PEM-HHS-1X Halogen And Halides Sampling Equipment:


Q: How is the PEM-HHS-1X Sampling Equipment used for halogen and halide analysis?

A: The equipment is operated manually by introducing the sample through the tube and bottle inlet. You then monitor testing via the rotameter flow indicator and conduct analysis following BIS, ASTM, or IEC methods.

Q: What safety measures are integrated into the PEM-HHS-1X unit?

A: The unit features gas leak-proof joints and over-pressure protection to ensure operator safety during laboratory sampling procedures.

Q: Where can the PEM-HHS-1X be installed and used?

A: This equipment is designed for bench-top mounting in laboratory environments suitable for analytical halogen and halide determination.

Q: When should an external heating source be applied?

A: The PEM-HHS-1X operates unheated, but external heating may be required based on the analytical method and sample characteristics you are using.

Q: What are the benefits of the corrosion-resistant construction?

A: The mild steel epoxy powder-coated body and borosilicate glass components offer outstanding resistance to corrosion, ensuring durability and longevity even in demanding laboratory environments.

Q: How is the sampling tube replaced in the equipment?

A: The design allows for easy glass tube replacement, making maintenance straightforward and minimizing downtime during regular use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Stack Emission Monitoring Instruments Category

PEM-SAMS2 Sulfuric Acid Mist Sampling Equipment

PEM-SAMS2 Sulfuric Acid Mist Sampling Equipment

Minimum Order Quantity : 1 Piece

Accuracy : 2% (method dependent)

Specimen Size : Standard air sample volume (as per method)

Equipment Type : Sulfuric Acid Mist Sampler

Temperature : 5C 45C (Operating)

Response Time : Instantaneous (flow readout)

PEM-SES-1 Metal Emission Sampling Equipment

PEM-SES-1 Metal Emission Sampling Equipment

Minimum Order Quantity : 1 Piece

Accuracy : 2% of reading

Specimen Size : Standard filter (90 mm diameter)

Equipment Type : Metal Emission Sampling Equipment

Temperature : Ambient to 250C (sample line, heated)

Response Time : <5 seconds

PEM-SMK15 Stack Monitoring Kit

PEM-SMK15 Stack Monitoring Kit

Minimum Order Quantity : 1 Piece

Accuracy : 2% of reading

Specimen Size : Standard stack diameter

Equipment Type : Stack Monitoring Kit

Temperature : 0 to 50C

Response Time : <60 seconds

PEM-SSPM5-L1 Method 5 Stack Sampling Probe Modules

PEM-SSPM5-L1 Method 5 Stack Sampling Probe Modules

Minimum Order Quantity : 1 Piece

Accuracy : 2% of reading

Specimen Size : Compatible with standard filter holders (47 mm dia.)

Equipment Type : Stack Sampling Probe Module

Temperature : Max. 500C probe tube capability

Response Time : <5 seconds for pressure stabilization



Back to top