POLLTECH INSTRUMENTS PRIVATE LIMITED
GST : 27AAFCP5116Q1ZY

call images

Call us

07971550923( PIN:157)

PEM-SES-1 Metal Emission Sampling Equipment
PEM-SES-1 Metal Emission Sampling Equipment

PEM-SES-1 Metal Emission Sampling Equipment

MOQ : 1 Piece

PEM-SES-1 Metal Emission Sampling Equipment Specification

  • Features
  • Portable, corrosion-resistant, high-temperature capability
  • Measuring Range
  • 0.01 mg/m3 to 100 mg/m3 (depending on filter and analysis)
  • Resolution
  • 0.01 mg/m3
  • Humidity
  • Up to 95% RH (non-condensing)
  • Port Size
  • 1/4 inch NPT
  • Automation Grade
  • Semi-automatic
  • Frequency
  • 50 Hz
  • Gas Pressure
  • 0.5 - 2 bar
  • Application
  • Sampling of hazardous metal emissions in stack or duct
  • Temperature
  • Ambient to 250C (sample line, heated)
  • Display Type
  • Digital LCD
  • Max Height
  • 1.5 m (assembled)
  • Specimen Size
  • Standard filter (90 mm diameter)
  • Number of Specimens
  • Up to 5 samples/run
  • Operating Voltage
  • 230 V AC
  • Power Supply
  • 230 V AC, 50 Hz
  • Interface Type
  • Analog/Digital output
  • Accuracy
  • 2% of reading
  • Test Range
  • Low to high emission flows
  • Equipment Type
  • Metal Emission Sampling Equipment
  • Response Time
  • <5 seconds
  • Mounting Type
  • Portable, stand mounted
  • Usage
  • Industrial stack and duct emission monitoring
  • Capacity
  • Variable, based on filter type
  • Machine Weight
  • 18 kg
  • Test Speed
  • Adjustable, up to 5 L/min
  • Test Width
  • 90 mm filter holder
  • Test Stroke
  • Standard length 2 m (probe)
  • Control Mode
  • Manual/Automatic
  • Alarm System
  • Over-temperature and pressure alarms
  • Filter Material
  • Quartz or Glass Microfiber
  • Flow Meter Type
  • Rotameter and electronic
  • Data Logging
  • USB and SD card storage
  • Calibration
  • With NIST traceable standards
  • Ambient Conditions
  • 0 to 45C operating
  • Vacuum Pump Type
  • Oil-less rotary vane
  • Cooling System
  • Integrated impinger bath
  • Enclosure Protection
  • IP54
  • Sampling Method
  • Isokinetic sampling
  • Probe Material
  • Stainless steel 316L
  • Sample Line
  • Heated PTFE, up to 3 m
 

PEM-SES-1 Metal Emission Sampling Equipment Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

About PEM-SES-1 Metal Emission Sampling Equipment



Select the PEM-SES-1 Metal Emission Sampling Equipment for top-tier performance and precision in hazardous metal emission monitoring. This superior device offers special features such as isokinetic sampling, a choice of quartz or glass microfiber filters, and an oil-less rotary vane vacuum pump. Unbeatable in reliability, it includes an integrated impinger bath, heated PTFE sample lines, and dual-mode control. The system boasts special rate accuracy with NIST-traceable calibration and robust IP54 enclosure, making it ideal for demanding industrial environments. Enjoy advanced data logging, over-temperature, and pressure alarms for complete peace of mind.

Commercial Applications and Key Features

The PEM-SES-1 Metal Emission Sampling Equipment serves commercial sectors by enabling meticulous monitoring of hazardous metal emissions from industrial stacks or ducts. With semi-automatic usage, this machine is equipped for up to five samples per run and supports both manual and automatic control. Its superior features-such as a heated sample line, digital LCD display, and high-temperature resilience-ensure consistent, precise results. Robust construction and portable design make it an exceptional choice for industries with strict regulatory compliance demands.


Main Domestic Market and Sample Policy

PEM-SES-1 is primarily supplied and transported within India's expansive industrial sector. We offer sample availability to facilitate thorough evaluation before bulk purchase. Thanks to reliable transport services and prompt supply arrangements, users across the domestic market benefit from seamless access and support. Our clear sample policy ensures clients receive the necessary experience and information to make an informed procurement decision, enhancing satisfaction and confidence in the equipment's performance.


FAQ's of PEM-SES-1 Metal Emission Sampling Equipment:


Q: How does the PEM-SES-1 ensure accurate metal emission sampling?

A: The PEM-SES-1 guarantees accuracy through isokinetic sampling, NIST-traceable calibration standards, and precision components like rotameter/electronic flow meters and a digital LCD display, achieving results with 2% accuracy.

Q: What are the main features that make this equipment suitable for industrial application?

A: Key features include a corrosion-resistant stainless steel probe, heated PTFE sample lines, integrated impinger bath cooling, portable stand-mounted enclosure, IP54 protection, and robust alarms for unmatched operational reliability in harsh conditions.

Q: When should periodic calibration and maintenance be performed?

A: Periodic calibration should follow regulatory guidelines or internal quality schedules, typically before and after each significant project or minimum annually, ensuring accuracy and compliance with industrial standards.

Q: Where can the PEM-SES-1 be transported and installed?

A: The equipment is primarily supplied and transported within India and can be installed conveniently on-site at industrial stacks, ducts, or emission points, thanks to its portable, stand-mounted design.

Q: What is the process for receiving a sample and understanding the sample policy?

A: Clients can request sample availability through supply channels. Our transparent sample policy ensures timely sample transport and sufficient testing time for clients to evaluate before committing to larger purchases.

Q: How does the data logging feature benefit industrial monitoring?

A: The USB and SD card data logging capability allows users to effortlessly store, retrieve, and analyze sampling data, supporting in-depth process optimization, regulatory reporting, and operational traceability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Stack Emission Monitoring Instruments Category

PEM-SAMS2 Sulfuric Acid Mist Sampling Equipment

PEM-SAMS2 Sulfuric Acid Mist Sampling Equipment

Minimum Order Quantity : 1 Piece

Port Size : 6 mm (tubing connection)

Automation Grade : Manual

Gas Pressure : Atm. pressure to 1 kg/cm2

Application : Sulfuric acid mist collection and environmental monitoring

Temperature : 5C 45C (Operating)

PEM-MESE1 Metal Emission Sampling Equipment

PEM-MESE1 Metal Emission Sampling Equipment

Minimum Order Quantity : 1 Piece

Port Size : Standard: 47 mm

Automation Grade : Semiautomatic

Gas Pressure : 02 bar

Application : Metal emission air quality monitoring

Temperature : 0C 50C

PEM-SMK20 Stack Monitoring Kit

PEM-SMK20 Stack Monitoring Kit

Minimum Order Quantity : 1 Piece

Port Size : 1/4 inch NPT

Automation Grade : Automatic

Gas Pressure : 07 kg/cm2

Application : Stack emission monitoring, Flue gas analysis

Temperature : 050C

PEM-HHD1X Halogen And Halides Sampling Equipment

PEM-HHD1X Halogen And Halides Sampling Equipment

Minimum Order Quantity : 1 Piece

Port Size : G1/4

Automation Grade : Semiautomatic

Gas Pressure : 0.10.7 MPa

Application : For determination of halogen and halide content in solid, liquid or gaseous substances

Temperature : 5C40C



Back to top